The Cyber-Terra CTLC Vibrating Wire Load Cell is designed for long-term monitoring of the anchoring conditions of prestressed tendons in hydraulic structures and other concrete structures, rock slopes, and bridges. It can simultaneously measure the temperature at the installation point. The CTLC features automatic temperature compensation, with a temperature correction coefficient smaller than the minimum readable unit, eliminating the need for any temperature correction during use.
Structure and Operating Principle
The Cyber-Terra CTLC load cell consists of a measuring steel cylinder, an outer protective casing, vibrating wires, and an observation cable.

| Model | CTLC | Storage Temperature | -40℃~+80℃ |
| Rated Load (P) | 0kN~5000kN | Temperature Resolution | ±0.1℃ |
| Maximum Load (Pm) | 0kN~6250kN | Temperature Accuracy | ±0.5℃ |
| Number of Vibrating Wires | 4 | Water Pressure Resistance | ≥0.5MPa |
| Resolution | ≤0.05%F.S | Insulation Resistance | ≥50MΩ |
| Linearity Accuracy | ≈0.1%F.S/0.5%F.S | Work Temperature | -30℃~+70℃ |
| Frequency Range | 2800HZ-2200HZ | Size | ID 65mm, OD110mm, Height 110mm |
Note: The frequency modulus F is calculated as F = Hz2×10-3.